A-A-51315
Sampling.
For examination and testing. Sampling for examination and testing shall be conducted in accordance with MIL-STD-105 and table I. The unit of product for sampling purposes shall be one complete unit as specified.
TABLE I. Sampling for examination and testing.
|
Inspection level |
AQL (defects per hundred units) |
For visual examination |
I |
1.0 |
Major defects Total defects (Major and Minor Combined) |
I |
4.0 |
For dimensional defects |
S-1 |
2.5 |
All tests |
S-2 |
0.0 |
For tests. Sampling for tests shall be conducted as follows:
a. First article. Where a first article sample is required, all tests shall be performed on that unit.
Acceptance testing. When a first article sample has not been required, one unit shall be subjected to all tests specified herein. If a first article sample has successfully passed all tests, performance testing shall not be required at acceptance.
Examination. The complete unit shall be examined to determine compliance with the requirements of this specification in accordance with the classification of defects in table II.
TABLE II. Classification of defects.
Categories |
Defects |
Major |
|
101 |
Any component missing. |
102 |
Any accessory part missing. |
103 |
Any par does not fit properly. |
104 |
Any movable part does not operate smoothly, and/or requires excessive force to operate. |
105 |
Tubing not free of any kink, crimb, or unspecified flatness. |
106 |
Any exposed or accessible surface not free of burrs or sharpness. |
Minor |
|
201 |
External surface not free of scratches or otherwise marred. |
202 |
Unit not clean, not free of dirt, oil, and grease. |
203 |
Service data missing or incomplete. |
204 |
Identification marking missing, incomplete, or illegible. |